Accepted Articles                   Back to the articles list | Back to browse issues page

XML Persian Abstract Print


1- Faculty of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran.
2- Department of Anatomy, Faculty of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran.
3- Department of Anatomy, Faculty of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran
Abstract:   (5 Views)
Introduction: Between traditional three-dimensional cadaveric dissection and the two-dimensional perspective there is a significant ‘cognitive gap’ that required for radiological interpretation. high costs, and labor-intensive fabrication techniques like plastination and digital three dimensional modeling offer potential solutions. present study introduces a novel, cost-effective protocol for fabricating high-resolution, axial Computed tomography (CT) scanning -based acrylic-sheet images sections.
Methods: We developed a novel method for producing high-resolution, axial CT-based anatomical sections by using 2mm transparent acrylic sheets. Twenty standardized axial CT images were selected from the hospital Picture Archiving and Communication System (PACS), optimized for educational clarity by using Adobe Photoshop, and printed onto 30×40 cm acrylic sheets via high-resolution flatbed printing technology. Interactive learning was facilitated by integrating quick response (QR) codes for supplementary data. To ensure durability and structural integrity, a protective second sheet was bonded to each print by using chloroform adhesive via a precision syringe application. Finally, the resulting models were evaluated for image quality, tactile robustness, and their suitability for frequent clinical anatomy training.
Results: High-resolution, axial CT sections were successfully fabricated by using bonded acrylic sheets. The chloroform-bonding technique produced durable, bubble-free, and cost-effective models. Integrated QR codes further enhanced interactivity to anatomical teaching aids.
Conclusions: this novel aid transforms axial CT images into robust, tactile educational tools. By combining high-resolution visual clarity with digital interactivity via QR codes, this method providing a practical and scalable pedagogical solution for training future clinicians.
     
Type of Study: Methodological Notes | Subject: Gross Anatomy
Received: 2026/08/17 | Accepted: 2026/11/25

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.